Nach ANSI / EIA-222-F 1996 |
||||
90 mph / 78 mph + 1/2″ Radial Eis w / (3 zweiter Bö) pro OBC UND altC |
||||
Problem |
Ratte Plattenbereich |
Gewicht |
Elevation |
|
kein Eis |
29.5 sq ft |
16.39 sq ft |
200 lbs |
160 ft |
1/2″ Icc |
36.0 sq ft |
20.00 sq ft |
350 lbs |
160 ft |
kein Eis |
50.0 sq ft |
27.78 sq ft |
350 lbs |
160 ft 130 ft |
1/2″ Eis |
60.5 sq ft |
33.61 sq ft |
600 lbs |
160 ft 130 ft |
(1)A7/8″ Koax Elevation 0 ft 160 ft |
||||
Kletterleiter □ evation 0 ft 140 ft |
||||
70 mph / 61 mph + 1/2″ Radial ice (Schnellster MPH) pro 0A-222-F |
||||
Problem |
Flachplattenbereich |
Gewicht |
Elevation |
|
kein Eis |
30.0 sq ft |
16.67 sq ft |
200 lbs |
160 ft |
1/2″ Eis |
36.5 sq ft |
20.28 sq ft |
350 lbs |
160 ft |
kein Eis |
51.5 sq ft |
28.61 sq ft |
350 lbs |
160 ft 130 ft |
1/2″ Eis |
61.5 sq ft |
34.17 sq ft |
600 lbs |
160 ft 130 ft |
(1)A7/8″ Koax Elevation 0 ft 160 ft |
||||
Steigleiter Elevation 0 ft 140 ft |
PIPE LEGS 42 KSI MIN ERTRAG 10 GA TUBE LEGS 30 KSI MIN ERTRAG
ANKER OLTS AMERICAN TOWER, 1„0 x 3’A6“MIN VERANKERUNG IN BETON.
180* ENDHAKEN PRO ACL SIEHE ZEICHNUNGEN VON AMERICAN TOWER FÜR DIE AUSRICHTUNG DER ANKERSCHRAUBEN.
#5 @ T MAX C/C-TOP EA WEG
#5 © T max C/C-j I FIN GRADE-
BOT EA WAY
ANMERKUNGEN:
1. ALLER BETON MUSS EINE MINDESTDRUCKFESTIGKEIT VON 3000 PS @ 28 TAGE.
2. BEWEHRUNGSSTAHL MUSS DEN ANFORDERUNGEN VON ASTM A615 ENTSPRECHEN (KLASSE 60).
3. GESAMTBETON = 35.6 cbm.
4. FUNDAMENTGESTALTUNG AUF DER BASIS DES FOLGENDEN:
LASSEN Anpreßdruck: 2000 PSF
GEWICHTSEINHEIT: 100 PCF
WASSER UND ROCK UNTER DEM FUSS LIEGT
MAT FOUNDATION
https://www.abtersteel.com/structural-pipe/galvanized-pipe/
160* STANDARD |
STIFTUNG |
|
DURCH: DOW |
DATUM: 12/21/02 |