Shop Detailing and Estimation Before leaving the Manufacturer’s Works all tower members shall be hard stamped with distinguishing numbers and/or letters corresponding to distinguishing numbers and/or […]
B1.5.1 Design Loads Applied basic wind pressures shall be in accordance with those specified in B2.5.8 above. The design shall be based on the following considerations:- […]
B1.5.3 Sizing of Tower Members Member and member connection design sizing shall be performed in accordance with the latest issue of Guide for Design of […]
B1.5.1 Design Requirements The unit stresses in members and connections for the structural design calculation, based on the design loading and design unbalanced loading (broken wire […]
B1.5.6 Types of Towers a) Tower structures shall be of the self-supporting lattice type steel frame with square bases. The general outlines of the towers, the […]
Transmission line Steel Tower Galvanizing Requirements Except where specified to the contrary, all iron and steel used in the construction of the Contract Works shall be […]
INTRODUCTION The works covered by these Technical Specifications form part of the Interconnection System Reinforcement Project. This part of the project consists of the design, manufacture, […]